-
Liquid Chromatography Instrument
-
Ion Chromatography Instrument
-
Helium Leak Detector
-
Atomic Absorption Spectrophotometer
-
Chromatography Columns
-
PCR Analyzer
-
Ultrasonic Scalpel System
-
Ambient Air Quality Monitoring Instruments
-
Continuous Emissions Monitoring System
-
Continuous Water Monitoring Equipment
-
Vacuum Leak Detection System
-
Gas Chromatography Instrument
-
Pressure Leak Detector
-
UV Visible Spectrometer
-
HPLC Detector
-
Continuous Flow Analyzer
-
F*CorpI was satisfied to work with such a professional team; they went above and beyond to ensure that I had all the information necessary to purchase my analytical instrument. Client from India
-
A*A.SI enjoyed working with Wayeal's team members, they were also friendly, positive, and professional. They come highly recommended and anyone would be lucky to have them as their agent. Client from Turkey
-
T*SpI purchased two analytical instruments from Wayeal and was pleased with them. Delivery was fast, and the order process was easy. Client from Chile
GB11893-89 Continuous Water Monitoring Equipment for Measuring Total Phosphorus WS1504
Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xProduct Name | Continuous Water Quality Monitoring Equipment For Measuring Total Phosphorus | Product Size | 380*470*600mm |
---|---|---|---|
Application | Surface Water | Range Drift | ≤±5% |
Linearity | ≤±5% | Zero Drift | ≤±5% |
High Light | GB11893-89 Continuous Water Monitoring Equipment,WS1504 Continuous Water Monitoring Equipment,Water total phosphorus analyzer |
Continuous Water Quality Monitoring Equipment for Measuring Total Phosphorus
Product Introduction
The potassium persulfate oxidation-ammonium molybdate spectrophotometry is adopted for WS1504 continuous water quality monitoring uquipment for total phosphorus content. In an acidic medium, orthophosphate reacts with ammonium molybdate to generate phosphomolybdenum heteropolyacid in the presence of antimony salt, which is immediately reduced by ascorbic acid to form a blue complex. This substance has a maximum absorption at 700nm. According to the Lambert-Beer law, the total phosphorus content in the water sample is measured through the photoelectric colorimetric method.
Product Parameter
Product Name | Continuous Water Quality Monitoring Equipment for Measuring Total Phosphorus |
Measurement Method | Potassium persulphat oxidation - ammonium molybdate spectrophotometric method |
Measurement Error | ≤±3% |
Zero Drift | ≤ ±5% |
Measurement Range | 0.05~50mg/L |
Repeatability | ≤ ±5% |
Range Drift | ≤±1% |
Product Performance
1. GB 11893-89 Water Quality - Determination of Total Phosphorus - Ammonium Molybdate Spectrophotometric Method is adopted.
2. The unique three-stage precision photoelectric metering device is used to realize fast and accurate reagent extraction and greatly reduce the impact of peristaltic pump tube aging;
3. Automatic electronically controlled safety gates are designed to take care of the safety of equipment operators and maintenance personnel.
Product Application
Sewage Treatment Plant, Enterprise Outfall